Hotline:13328402352

Product

product

Current location: Xiamen Lingzhao > Product > MTL

MTL safety barrier / Eaton safety barrier ICC441 single channel analog input safety barrier

Product introduction

The MTL ICC441 safety barrier is a single-channel analog input safety barrier. The following is a detailed introduction: Signal processing: supports 0/4-20mA analog signal input and bidirectional HART communication (transparent

Product model:ICC441
Update time:2025-07-28
Manufacturer nature:Source manufacturer
Visits:
Detailed introductionLeave a message online

The MTL safety barrier ICC441 is a single-channel analog input safety barrier. The following is its detailed introduction:

  • Signal processing: supported 0/4-20mA analog signal input, supports bidirectional HART communication (transparent transmission mode), and can be used for two-wire and four-wire instrument connection.

  • Functional Features: Utilizing optoelectronic isolation technology, this device can isolate and convert analog signals from hazardous areas and transmit them to safe areas, preventing hazardous energy from entering the area and ensuring system safety. With intrinsic safety certification, it can be used in explosion-proof Zone 2.

  • Technical Parameters: Standard accuracy is ±0.1% FS, temperature drift is ±0.015%/℃, response time ≤1s (0-90%), stabilization time ≤3s. The power supply voltage fluctuation is ±0.1%/250V, the maximum explosion-proof voltage is 250VAC, and the explosion-proof grade mark is (Exia) IC.

  • Installation method: DIN rail installation is usually adopted, which is convenient for installation and wiring in industrial control cabinets.

  • Application fields: Widely used in industrial fields such as petroleum, chemical, electric power, and metallurgy, it is used to achieve safe transmission of analog signals between safe and hazardous areas. For example, it can connect pressure transmitters and temperature transmitters in hazardous areas, isolate and convert their output analog signals, and then transmit them to the control system in the safe area.

1.jpg

2.jpg

WeChat picture_20250721110111_25.png

微信图片_20250721110111_26.jpg

微信图片_20250721110111_20.jpg

微信图片_20250721110111_23.jpg

MTL safety barrier/Eaton safety barrier ICC441   Single-channel analog input safety barrier

MTL safety barrier/Eaton safety barrier ICC441   Single-channel analog input safety barrier


We have the discontinued spare parts you urgently need here,

Complete models and sufficient stock! In stock in seconds, great prices!

Sales Manager: Liu Jing

E-mail: 3918466031@qq.com | Phone/WeChat: 13328402352


Leave a message online

Message box

  • Product name:

  • your organization:

  • your name:

  • Contact number:

  • Commonly used emails:

  • province:

  • Detailed address:

  • Message content:

Copyright © 2025 Xiamen Lingzhao E-Commerce Co., Ltd. All rights reserved

SiteMap

Manager Liu
Follow

Connect

13328402352

Connect
Top